What exactly is the difference between a surge protector and a fuse? Can a fuse protect the electronic devices from lightning instead of surge protector?
09.06.2025 00:48

[image of Common-mode choke]
Can the fuse protect the electronic devices from lightning instead of a surge protector.
Edit 2024–10.
Is it possible to permanently quit pornography?
OK, this is Mohan Rajaratnam’s definition of a Surge suppressor.
So, it’s possible that these devices from Trip Lite have addition suppression devices, these ones seem to be sturdy.
First Sentence:
A fuse is a non-resetable over current circuit protector.
An AC voltage/ current source, and an ac inductive load.
Is the question then , "why buy a surge supressor, if the fuse alone protects the electronic circuits from a lightning bolt?".
As a teacher, what's the most inappropriate experience you've had with a student?
2024–10–14 [Omar Gharbi Omar Gharbi ]
2024–10–11 [Victor Olarewsju Victor Olarewaju ]
Lightning arrestor is a spark-gap device, and can be installed anywhere. What is important, is that the wire is thick enough to withstand the lightning bolt and conduct the energy away from the building.
This is an electronic circuit designed to clamp voltages so that the Voltage Potential that appears at the outlet is never going to exceed the nominal value.
“ A surge suppressor is the one which is connected at the input supply so that when there is a sudden change voltage it bypasses thereby protecting the (circuit) and electronic components”
Now when you have a certain ac resistance, then a current flows in a loop.
Could Mauricio Pochettino leave USMNT for Tottenham?: 'It's not realistic' - FOX Sports
2024–10–16 [ OO OLAOYE OYEBODE ]
One
It seems Mohan does not understand the difference between a comment and an Answer.
In schematic diagrams this is the symbol for a fuse:
a photo is worth a thousand words.
The other is “what does a “fuse” do?”
He then describes the function of a fuse.
eight
Fuses, on their own, then operate much slower than the MOV variable resistance, during the lightning strike.
What are your darkest taboo confessions?
The bolt then partially travels down the line to your home.
I post the exact comment here.
But it can get overloaded, and no longer works.
At one ohm, the resistor has a maximum of 1 watt power.
2024–09–27 [ Mohan Rajaratnam Mohan Rajaratnam ] . Thinks you can get free electricity from nothing : Mohan Rajaratnam's answer to Is it possible to generate free electricity at home using a magnet or other low-cost methods? If so, how does it work?
He then describes Rainy Season and Lightning.
What do you think about a sister's love?
But during the surge, the fuse will not blow if it is a longer duration and lower value )10 to 50%).
This is 'the assistant's answer'
This is a high voltage low current spike that comes down the line because of the power poles being struck, and the voltage suppressors activating on the primary side of the transformer.
It’s been three xxx five werks, and there has been no response to my follow on query on his Commment to my answer.
Because the load is inductive, the current lags the voltage.(by a bit).
It also is a device that limits the change in current flow.
At the secondary, it is 1000 times less.)turns ratio). If it gets hit with a 100,000 volt bolt of lightning then the voltage arrestors conduct and clamp the voltage down to line voltage, ( but a small amount leaks down the line). This is the problem.
If the nominal power is 4,000 watts then the current at 230volts is 16 amps.
The MOV will conduct when the voltage exceeds 50% of line voltage.
2024–10–10[John johnson John Johnson ]
Once the voltage goes over 0.0650 volts, then this fact can be used to amplify the difference, and turn the circuit breaker off , furthur down the line. Essentially that is what a RCD/GFCI does, it compares the incoming current, to the outgoing current, and if the difference between the two currents is over 5mA, then it trips the circuit breaker.
so, what happens?
A circuit breaker is similar, but is resettable.
These devices are installed between the “hot” and “neutral” and protective ground.
Upvotes:
What is lightning?
This is a photo where a lightning bolt took out a home's complete mains distribution box, and a lot of electronic gear as well.
what exactly is a ‘surge’ protector?
These are simplified answers to the original question, and does not change anything I wrote above.
(There is no concept of polarity, in the loop because the current changes direction 100 to 120 times a second (power frequency).
What does a fuse do?
This one hit behind the barn.
This device then solves the entire problem.
nine
So, the voltage could go up to 500 volts, and the fuse will not open up.
At least they know the answer if they wanted it.
Mohan forgets that a fuse is a one-time device, and needs to be replaced if it is tripped.
For this case there are devices called Metal oxide varistors (MOV).
Here is a simplified AC power diagram.
but this device (an Inductor) … impedes the rapid changes in the current.
But… the neutral is now “floating” because of the 1 ohm resistance.
2024–10–00 [ Ammar Mahdi ] Ammar Mahdi
One is “what exactly is in a ‘surge protector’ ? ”
“ … to protect building, lightning arrestor, is provided above building and directly connected to earth.”
And this is the problem alone. Is the power supply in the equipmemt designed with a lightning strike in mind? Some yes, others, no.
so, the loop of wire then, when put together with another loop reduces the ‘noise’ on a power line.
There are two important concepts here.
This is where the MOV conducts again, and dissipated the energy.
(Dc diagram shown, AC is similar).
This is where this question deviates from being a 'generic' question, and becomes more specific.
The third is lightning and “how it gets conducted into a home.”
When the current is 200% of the rated value , it will “go open” (the link metal melts) and protect the device.
He then asserts :
but I think this circuit , shows a few more pieces.
There are three different concepts here that are getting confused.
There is no harm in having the surge suppressor along with the fuse in the circuit. The fuse will not open up until the current melts the link. This will take time, and in the interim, that jolt will get transmitted into the power supplies.
This is the picture of an electronic coil of wire wound around a core of magnetic material.
Would individual surge supressors have save this equipment? most likely, since the surge supressor would take the jolt instead of the electronic components.
2024–10–11 [Bobby Sanchez Bobby Sanchez ].
the problem then depends on "how fast does the fuse operate?".
[old diagram got deleted by accident]
P = e* I, so since I is 16 amps, then the voltage dropped is 1/16 volt or 0.0650 volts.
“ A fuse is a device which protects the (circuit) against overload and short circuit.”
Barnstars:
So combined with a device called a MOV or Metal-oxide-resistor, then forms the 3rd part of a “surge suppressor “.